Iatrogenic Tracheal Rupture from Endotracheal Tube Balloon Overinflation
Imaging findings
Chest radiograph and CT show extensive subcutaneous emphysema, severe pneumomediastinum, and a right-sided chest tube positioned directly through the lung parenchyma with surrounding pulmonary hemorrhage. On chest CT, there is a focal, 3 cm outpouching of the posterior membranous trachea at the level of the inflated endotracheal tube cuff, appearing similar to a vascular pseudoaneurysm. This finding was absent on the pre-intubation CT.
Key takeaways
Tracheal rupture is a rare but life-threatening mechanical complication of endotracheal intubation, most commonly involving the posterior membranous trachea. The injury can result from mechanical trauma during tube insertion or from overinflation of the cuff balloon, particularly when patient movement or coughing occurs. Rapid identification of a focal tracheal outpouching or worsening pneumomediastinum on CT should prompt urgent bronchoscopic evaluation and surgical repair.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Type A Aortic Dissection Spared by Anomalous Separate Origins of the Left Anterior Descending and Left Circumflex ArteriesCongenital
- Primary Pericardial AngiosarcomaNeoplastic
- Brown Tumors of Secondary HyperparathyroidismMetabolic
- Septic Pulmonary Embolism and Intracardiac Vegetation from Factitious Fecal InjectionInfection
- Acute Aortic Intramural Hematoma Extending into the Pulmonary Artery WallVascular
- Calcified Fibrothorax from Historical Tuberculosis Collapse TherapyInfection
- Left Atrial Endocardial Calcification following Radiofrequency Catheter AblationIatrogenic
- Amiodarone-Induced Pleural EffusionInflammatory
See all cases from June 10, 2017 →
Related Iatrogenic cases
- Iatrogenic Cerebrospinal Fluid Pleural Leak
- MR Lymphangiography for Postoperative Chylothorax
- Atrioesophageal Fistula Post-Atrial Fibrillation Ablation
- Delayed Hemothorax Post-First Rib Resection for Thoracic Outlet Syndrome
- Pulmonary Hemorrhage following CT-Guided Lung Biopsy
- Inadvertent Right Ventricular Lead Loop of a CRT-D Device