CTICases ← All cases

Left Ventricular Outflow Tract Obstruction by Mitral Valve Bioprosthesis

Imaging findings

Cardiac CT and three-chamber cinematic reconstructions demonstrate a surgically placed bioprosthetic mitral valve. A prominent valve strut is seen extending into and dynamically obstructing the left ventricular outflow tract (LVOT) during systole. Additionally, there is systolic anterior motion (SAM) of the adjacent chordae tendineae, which are dynamically drawn into the narrowed LVOT due to the Venturi effect.

Key takeaways

Dynamic left ventricular outflow tract (LVOT) obstruction is a potential complication of mitral valve replacement or repair. It can occur when bioprosthetic valve struts or retained native mitral valve tissue project anteriorly into the outflow tract, generating a Venturi effect that dynamically sucks the chordae or leaflet tissue into the LVOT during systole, leading to functional aortic stenosis.

AI-assisted summary — may contain errors. Verify against the source video. Learn more

More from this webinar

See all cases from April 20, 2017 →

Related Iatrogenic cases

Browse all Iatrogenic cases →