Imaging findings

Pockets of gas are observed within the esophagus, along with pneumomediastinum just outside the esophagus. Sagittal views show a linear string of gas in the mediastinum following the contour of the esophagus.

Key takeaways

This case demonstrates an esophageal perforation following a transesophageal echocardiogram (TEE), performed for TAVR sizing. The patient developed chest and neck pain post-procedure. Although subsequent swallow studies did not show a leak, the patient was managed conservatively with NPO status and recovered well. It's a rare but significant complication of TEE.