Retained Guidewire from Central Venous Catheter

Retained Guidewire from Central Venous Catheter▶ Watch on YouTube — age-restricted, cannot embed here

Imaging findings

Postoperative chest radiographs show an object projecting over the right ventricle, initially misinterpreted as a transvenous pacemaker. Closer inspection reveals it has the appearance of a floppy J-wire tip. The patient had multiple catheters, and the object was a retained guidewire from a triple lumen central venous catheter.

Key takeaways

It is crucial to accurately identify medical devices and distinguish them from others, especially in the postoperative setting. A retained guidewire is a known complication of central venous catheter placement, often occurring during emergent situations, and must be recognized to avoid patient harm.