CTICases ← All cases

Upside-down fluid level on CT from silicone breast implant rupture

Imaging findings

CT chest of a patient with a ruptured silicone breast implant shows an intracapsular rupture with a clear fluid-fluid level where the hyperattenuating (denser-appearing) silicone layer sits on top of the dependent, water-equivalent fluid layer.

Key takeaways

Because the atomic number of silicon (Z=14) is higher than that of carbon and oxygen, silicone attenuates X-rays more than water, making it appear hyperdense (white) on CT. However, its physical density is lower than water, creating a paradoxical 'upside-down' fluid level where the brighter silicone layer floats on top.

AI-assisted summary — may contain errors. Verify against the source video. Learn more

More from this webinar

See all cases from July 9, 2026 →