Partially extravasated triple-lumen central venous catheter
Imaging findings
Chest radiographs and CT show a left internal jugular triple-lumen catheter. A non-contrast CT shows extravascular contrast medium collection in the anterior mediastinum. A venous angiogram confirms that only the proximal port is intravascular, while the distal port extravasates contrast into the mediastinum due to catheter tip wall penetration.
Key takeaways
Multi-lumen catheters can be partially extravasated, with one port positioned intravascularly and another positioned extravascularly. Checking blood return or flushing from only one port may fail to detect partial extravasation, highlighting the importance of verifying all ports.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Recurrent marginal zone B-cell lymphoma of MALTNeoplastic
- Primary pulmonary marginal zone B-cell lymphoma of MALTNeoplastic
- Metastatic breast cancer presenting as malignant pleural effusionNeoplastic
- Birt-Hogg-Dube syndromeCongenital
- Superior vena cava diverticulumCongenital
- Eosinophilic granulomatosis with polyangiitis with severe lymphadenopathyAutoimmune
- Suboptimal CT pulmonary angiography demonstrating acute pulmonary embolismVascular
- Solitary fibrous tumor of the pleuraNeoplastic
See all cases from January 4, 2019 →
Related Iatrogenic cases
- Pulmonary vein occlusion post-radiofrequency ablation causing bronchial venous engorgement
- Venous infarction from pulmonary vein occlusion
- Tracheal stenosis from prior intubation
- Iatrogenic chest wall hematoma from thoracentesis
- Pulmonary artery catheter-induced pseudoaneurysm
- Aspiration bronchiolitis from esophageal mucositis