Ruptured Post-Operative Aortic Root Pseudoaneurysm
Imaging findings
Immediate post-operative CT angiography following a type A aortic dissection repair (including aortic valve, root, and ascending aortic graft replacement) shows a tiny, localized pseudoaneurysm at the distal suture line of the aortic root graft. On a follow-up gated CT angiography obtained four months later, this small pseudoaneurysm has ruptured, demonstrating a large, blood-filled cavity with contrast extravasation extending along the length of the ascending aortic graft, representing a contained rupture held by the adventitia.
Key takeaways
Small, iatrogenic pseudoaneurysms at graft anastomosis or suture sites are relatively common incidental findings on post-operative imaging after aortic reconstruction. While many remain stable and are managed conservatively, they carry a risk of progressive enlargement and catastrophic rupture, highlighting the necessity of careful surveillance imaging.
AI-assisted summary — may contain errors. Verify against the source video. Learn more
More from this webinar
- Solitary Fibrous Tumor of the PleuraNeoplastic
- Chronic Vaping-Induced Lung FibrosisExposure
- ROR1 CAR T-Cell Therapy-Induced Cytokine Release SyndromeInflammatory
- Ruptured Dobhoff Feeding TubeIatrogenic
- Foreign Body Granuloma from BioSentry Biopsy Tract SealantInflammatory
- Circumflex Aortic ArchCongenital
- Double Aortic Arch with Atretic Left Segment and Secundum ASDCongenital
- Pulmonary HistoplasmosisInfection
See all cases from April 30, 2021 →
Related Vascular cases
- Type B Aortic Dissection with Patent False Lumen
- Giant Ascending Aortic Aneurysm and Chronic Type A Dissection
- Pulmonary Arterial Hypertension associated with Neurofibromatosis Type 1
- Chronic Thromboembolic Pulmonary Hypertension (CTEPH) with Pulmonary Artery Compression of Left Coronary Artery
- Severe CTEPH in a Young Adult with Systemic-to-Pulmonary Collaterals
- Concurrent Venous, Pulmonary Arterial, and Aortic Thrombus (Hypercoagulable State)